Hi gromacs people,

I was trying to rerun old xtc trajectories to recalculate some energies involving the solvent, using gmx 3.3.1. I saw important discrepancies with the original energies (nstlist=1, xtc unaccuracy tolerated). After some struggling, I figured out that the box size is determined form the .gro file used to create the .tpr file, and are not read from the trajectory. I then realized that this problem had been described two years ago on the list:

   http://www.gromacs.org/pipermail/gmx-users/2005-October/017729.html

The issue was then transferred to bugzilla :

   http://bugzilla.gromacs.org/show_bug.cgi?id=26

and a patched md.c was proposed by David, apparently for gromacs 3.3.0. It seems that this patch has not been integrated in gmx 3.3.1, because the -rerun option still gives wrong energies. What's worse, the patched md.c cannot be used for 3.3.1, because apparently the number of arguments for init_md() has changed.

Could someone work out a patch for 3.3.1, and maybe post it on the same bugzilla thread?

I think this bug should be mentioned in the "known bugs" section of the website. That would probably save some sweat to others like me trying to use the -rerun option...

Thanks,
Michel

--

==========================================================
Michel Cuendet, Ph.D
Molecular Modeling Group
Swiss Institute of Bioinformatics
CH-1015 Lausanne, Switzerland
www.isb-sib.ch/groups/Molecular_Modeling.htm
==========================================================


_______________________________________________
gmx-users mailing list    gmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to