And if you're at it, also change your temperature coupling...(check the archives).
Tsjerk On 5/21/07, Mark Abraham <[EMAIL PROTECTED]> wrote:
Stéphane Téletchéa wrote: > While switching from NVT to NPT, i'm crashing my simulation. > > The error message seen is (repeated 10 times, then mdrun aborts): > ##### > Step 1 Warning: pressure scaling more than 1%, mu: -1.59647e+20 > -1.59647e+20 -1.59647e+20 > Correcting invalid box: > old box (3x3): > old box[ 0]={-9.82630e+20, 0.00000e+00, -0.00000e+00} > old box[ 1]={ 0.00000e+00, -8.90833e+20, -0.00000e+00} > old box[ 2]={ 0.00000e+00, 0.00000e+00, -1.12456e+21} > new box (3x3): > new box[ 0]={-9.82630e+20, 0.00000e+00, -0.00000e+00} > new box[ 1]={ 0.00000e+00, -8.90833e+20, -0.00000e+00} > new box[ 2]={ 0.00000e+00, 8.90833e+20, -1.12456e+21} > ..... > ------------------------------------------------------- > Program mdrun_lam, VERSION 3.3.1 > Source code file: ns.c, line: 265 > > Fatal error: > Box was shifted at least 10 times. Please see log-file. > ------------------------------------------------------- > ##### > > I've searched in the archives this could be related to a non > sufficiently equilibrated system, but the first 20ps NVT run fine, so i > presume there's either a problem in the way i'm doing it (thus the > RFC-like question from the other message) or i'm missing something obvious. > > Since i've tried to eliminate many errors and still get these errors > after different trials (removing shuffle and sort, generating or not > velocities while switching from pr1 to pr2, i've also tried the > "unconstrained_start=yes"). You will want to use unconstrained_start=yes in any restart of a simulation using constraints with which you're attempting to be exact. > If you have any pointer, i'll be very happy to read it ... > > I'm still looking at my setup system (protein in a water/spc solvent) in > order to find where is my error, but since the NVT run seems ok > (analysing precisely it at the moment, but no visual problem neither any > hint in the logs), i'm willing to understand why the switch to NPT fails. As I think DvdS is hinting, if your box volume is such that the system is of the wrong size, then a sudden switch to NpT with a short time constant will cause a big perturbation to the system. This can break stuff. Check pressures, densities and volumes. To fix, either use a long time constant with NpT (and wait a while), or choose the volume with editconf so as to get the right outcome for the switch to NpT. Mark _______________________________________________ gmx-users mailing list gmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED] Can't post? Read http://www.gromacs.org/mailing_lists/users.php
-- Tsjerk A. Wassenaar, Ph.D. Junior UD (post-doc) Biomolecular NMR, Bijvoet Center Utrecht University Padualaan 8 3584 CH Utrecht The Netherlands P: +31-30-2539931 F: +31-30-2537623 _______________________________________________ gmx-users mailing list gmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED] Can't post? Read http://www.gromacs.org/mailing_lists/users.php