Use semiisotropic pressure coupling with with the compressibility and
reference pressure both 0 in the xy dimension.
Bob


On 2/15/07, toma0052 <[EMAIL PROTECTED]> wrote:
Hello,
     I am looking to do a membrane simulation where I have a constant
pressure normal to the membrane, and a fixed area of the membrane.  Being
semi-unfamiliar with pressure coupling schemes, how would I do this in
Gromacs?  It seems that even if I use the semiisotropic pressure coupling
scheme, the simulation box will rescale to maintain whatever pressure I name
for the x and y directions.  I want the x and y box dimensions to stay fixed
with only the z box dimension allowed to fluctuate, as done by
Sankararamakrishnan and Weinstein, 2004.

Thank you,
Mike

_______________________________________________
gmx-users mailing list    gmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please don't post (un)subscribe requests to the list. Use the
www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

_______________________________________________
gmx-users mailing list    gmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to