First, with rlist = rvdw, you will not get long range Lennard Jones interactions. In fact I would recommend using a larger vdw cut-off, as 0.9 is very short. Are you sure you are using the same mdp file?

About the LR coulomb, it will only appear if you have rlist < rcoulomb. In that case the sphere between rlist and rcoulomb is frozen for the direct electrostatic interaction calculation during PME between two nlist updates (set by nlist = X).

Gerrit

Luca Mollica wrote:

Hi,

having started to use GMX 3.3 since few months, I have a doubt about using PME treatement for electrostatics and extracting energies from the corresponding .edr file.

After simulation, trying to use g_energy -f energy.edr -o Energy.xvg, I get the following groups:

[...]
Mu-Y                    Mu-Z                    Coul-SR:Protein-Protein
LJ-SR:Protein-Protein   Coul-14:Protein-Protein LJ-14:Protein-Protein
Coul-SR:Protein-SOL     LJ-SR:Protein-SOL       Coul-14:Protein-SOL
LJ-14:Protein-SOL       Coul-SR:Protein-Cl      LJ-SR:Protein-Cl
Coul-14:Protein-Cl      LJ-14:Protein-Cl        Coul-SR:SOL-SOL
LJ-SR:SOL-SOL           Coul-14:SOL-SOL         LJ-14:SOL-SOL
Coul-SR:SOL-Cl          LJ-SR:SOL-Cl            Coul-14:SOL-Cl

[...]

I have notice a difference with respect to 3.2 version of GMX, that is the absence of LR terms for both LJ and Coulombic terms: 3.2 provides a LR term for PME calculations, 3.3 does not provide it. Now, what about the missing terms ? Considering the theory that stays behind the Ewald sums, the SR term should include only the real part, but I cannot understand quite well what I have to do with the 'missing' reciprocal + dipolar + self LR term ....

Please consider that I have used the following terms for energy calculations:

pbc                 =  xyz
ns_type             =  grid
rlist               =  0.9
rcoulomb            =  0.9
fourierspacing      =  0.12
pme_order           =  4
rvdw                =  0.9
coulombtype         =  PME
ewald_rtol          =  1e-5

which corresponds to pretty standard PME parameters .... and also, testing Cut Off treatement of electrostatics, I get back the LR and SR term.

ThanX to you all




    Luca




::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::

Luca Mollica
Dulbecco Telethon Institute
c/o DIBIT - S. Raffaele Scientific Institute
Biomolecular NMR Laboratory, 1B4
Via Olgettina 58
20132 Milano Italy

Tel: 00390226433497
Fax: 00390226434153


An expert is a man who has made all the mistakes
which can be made in a narrow field.

(Niels Bohr)



********************************************************************
Sostieni la ricerca del San Raffaele con il 5permille!
E' SEMPLICE E NON COSTA NULLA.
Basta indicare nell'apposito riquadro della dichiarazione dei
redditi ("Ricerca sanitaria") il codice fiscale della Fondazione Centro S. Raffaele del Monte Tabor:
03 06 42 80 153 e ricordarsi di firmare.
Se vuoi saperne di piu' scrivi a [EMAIL PROTECTED] o vai sul sito
www.5xmille.org
_______________________________________________
gmx-users mailing list    gmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php


_______________________________________________
gmx-users mailing list    gmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to