> But now for the most important question: is there a reproducible problem 
> with the angle?
Yes. I include everything into a tar:

http://biocroma.unizh.ch/gianluca/Files/Gromacs/hbond.tar.bz2

I'm using the following command to verify if the hydrogen bond "ARG 552
HH12 - GLN 548 OE1" is formed along the trajectory:

g_hbond -f trajectory.trr -s topol.tpr -r 0.27 -a 60 -n select.ndx -noda
-nonitacc -hbm -hbn -nomerge

File "hbmap.xpm" tells me that the hbond is formed in only three frames.
However, if I plot the distance with g_dist and the angle with g_angle as
a function of time (see dist.xvg and angaver.xvg) the distance between
hydrogen and acceptor is below 0.27 nm in 61% of the frames and the angle
(ADH) is below 60 degrees in almost all frames. All used commands are in
the file "commands".

Thanks a lot for your help,

Gianluca


-----------------------------------------------------
Dr. Gianluca Interlandi [EMAIL PROTECTED]
                    +1 (206) 685 4432
                    +1 (206) 714 4303
                    http://biocroma.unizh.ch/gianluca/