I would leave it on 64M in volumes with spindle disks, but with SSD volumes, I would increase it to 128M or even 256M, but it varies from one workload to another. On Wed, Jan 27, 2021 at 10:02 PM Erik Jacobson <[email protected]> wrote:
> > Also, I would like to point that I have VMs with large disks 1TB and > 2TB, and > > have no issues. definitely would upgrade Gluster version like let's say > at > > least 7.9. > > Great! Thank you! We can update but it's very sensitive due to the > workload. I can't officially update our gluster until we have a cluster > with a couple thousand nodes to test with. However, for this problem, > this is on my list on the test machine. I'm hoping I can reproduce it. So > far > no luck making it happen again. Once I hit it, I will try to collect more > data > and at the end update gluster. > > What do you think about the suggestion to increase the shard size? Are > you using the default size on your 1TB and 2TB images? > > > Amar also asked a question regarding enabling Sharding in the volume > after > > creating the VMs disks, which would certainly mess up the volume if that > what > > happened. > > Oh I missed this question. I basically scripted it quick since I was > doing it so often.. I have a similar script that takes it away to start > over. > > set -x > pdsh -g gluster mkdir /data/brick_adminvm/ > gluster volume create adminvm replica 3 transport tcp > 172.23.255.151:/data/brick_adminvm > 172.23.255.152:/data/brick_adminvm 172.23.255.153:/data/brick_adminvm > gluster volume set adminvm group virt > gluster volume set adminvm granular-entry-heal enable > gluster volume set adminvm storage.owner-uid 439 > gluster volume set adminvm storage.owner-gid 443 > gluster volume start adminvm > > pdsh -g gluster mount /adminvm > > echo -n "press enter to continue for restore tarball" > > pushd /adminvm > tar xvf /root/backup.tar > popd > > echo -n "press enter to continue for qemu-img" > > pushd /adminvm > qemu-img create -f raw -o preallocation=falloc /adminvm/images/adminvm.img > 5T > popd > > > Thanks again for the kind responses, > > Erik > > > > > On Wed, Jan 27, 2021 at 5:28 PM Erik Jacobson <[email protected]> > wrote: > > > > > > Shortly after the sharded volume is made, there are some fuse > mount > > > > messages. I'm not 100% sure if this was just before or during the > > > > big qemu-img command to make the 5T image > > > > (qemu-img create -f raw -o preallocation=falloc > > > > /adminvm/images/adminvm.img 5T) > > > Any reason to have a single disk with this size ? > > > > > Usually in any > > > virtualization I have used , it is always recommended to keep it > lower. > > > Have you thought about multiple disks with smaller size ? > > > > Yes, because the actual virtual machine is an admin node/head node > cluster > > manager for a supercomputer that hosts big OS images and drives > > multi-thousand-node-clusters (boot, monitoring, image creation, > > distribution, sometimes NFS roots, etc) . So this VM is a biggie. > > > > We could make multiple smaller images but it would be very painful > since > > it differs from the normal non-VM setup. > > > > So unlike many solutions where you have lots of small VMs with their > > images small images, this solution is one giant VM with one giant > image. > > We're essentially using gluster in this use case (as opposed to > others I > > have posted about in the past) for head node failover (combined with > > pacemaker). > > > > > Also worth > > > noting is that RHII is supported only when the shard size is > 512MB, so > > > it's worth trying bigger shard size . > > > > I have put larger shard size and newer gluster version on the list to > > try. Thank you! Hoping to get it failing again to try these things! > > > > > > > > -- > > Respectfully > > Mahdi > -- Respectfully Mahdi
________ Community Meeting Calendar: Schedule - Every 2nd and 4th Tuesday at 14:30 IST / 09:00 UTC Bridge: https://meet.google.com/cpu-eiue-hvk Gluster-users mailing list [email protected] https://lists.gluster.org/mailman/listinfo/gluster-users