si c'est de l'arista, il faut souvent passer un speed forced 10fgfull sur l'interface
Cordialement Alexis Lameire Le jeu. 9 janv. 2020 à 10:20, Kevin Thiou <kevinth...@gmail.com> a écrit : > > Bonjour, > > je ne m'explique pas cette situation : > > sh int e 35 transceiver > If device is externally calibrated, only calibrated values are printed. > N/A: not applicable, Tx: transmit, Rx: receive. > mA: milliamperes, dBm: decibels (milliwatts). > Bias Optical Optical > Temp Voltage Current Tx Power Rx Power > Port (Celsius) (Volts) (mA) (dBm) (dBm) Last Update > ----- --------- -------- -------- -------- -------- > ------------------- > Et35 20.10 3.36 14.55 -6.03 -6.77 0:00:00 ago > > sh int e 35 > Ethernet35 is down, line protocol is down (notconnect) > Hardware is Ethernet, address is 444c.a830.be8c (bia 444c.a830.be8c) > Ethernet MTU 9214 bytes , BW 1000000 kbit > Full-duplex, 1Gb/s, auto negotiation: off, uni-link: disabled > Down 9 hours, 6 minutes, 44 seconds > Loopback Mode : None > 11 link status changes since last clear > Last clearing of "show interface" counters never > 5 minutes input rate 0 bps (0.0% with framing overhead), 0 packets/sec > 5 minutes output rate 0 bps (0.0% with framing overhead), 0 packets/sec > 37272716 packets input, 10241947883 bytes > Received 42494 broadcasts, 27 multicast > 0 runts, 0 giants > 0 input errors, 0 CRC, 0 alignment, 0 symbol, 0 input discards > 0 PAUSE input > 61085627 packets output, 56045279287 bytes > Sent 0 broadcasts, 4264681 multicast > 0 output errors, 0 collisions > 0 late collision, 0 deferred, 0 output discards > 0 PAUSE output > > Le port en face est up. > > Quelque'un peut il m'expliqué ? > > Merci > > --------------------------- > Liste de diffusion du FRnOG > http://www.frnog.org/ --------------------------- Liste de diffusion du FRnOG http://www.frnog.org/