Yes,you need a time point exclusion file (-tpexclude filename option to 
mkanalysis-sess). Run mkanalysis with -help to get more info on how to 
create it.

On 01/25/2018 04:43 PM, Adam Martersteck wrote:
> Hi Freesurer experts,
>
> I’m looking to censor (drop volumes) from my resting state fMRI time 
> series that violate a predetermined motion and signal threshold (FD 
> and DVARS). I've already determined which volumes violate X and Y 
> criteria.
>
> Is there a way to to tell FS to "ignore" these time points in the 
> analysis such as in preproc-sess or mkanalysis-sess?
>
> If there is not and if I were to drop the volumes directly from the 4D 
> file before starting any pre-processing and analysis  – would that be 
> a problem for finding and regressing the auto-correlation in the time 
> series?
>
> Thanks!
> Adam
>
>
> _______________________________________________
> Freesurfer mailing list
> Freesurfer@nmr.mgh.harvard.edu
> https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer

-- 
Douglas N. Greve, Ph.D.
MGH-NMR Center
gr...@nmr.mgh.harvard.edu
Phone Number: 617-724-2358
Fax: 617-726-7422

Bugs: surfer.nmr.mgh.harvard.edu/fswiki/BugReporting
FileDrop: https://gate.nmr.mgh.harvard.edu/filedrop2
www.nmr.mgh.harvard.edu/facility/filedrop/index.html
Outgoing: ftp://surfer.nmr.mgh.harvard.edu/transfer/outgoing/flat/greve/

_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.

Reply via email to