Hi Doug thank you for the quick response!
The source is a Siemens scanner. Data derived from the Spine. I don't know what
is the optimal way to convert these ima images to nifti
what is the source of the ima file? was it anonymized? You can try something
like adding
-iid -1 0 0 -ijd 0 1 0 -ikd 0 0 1
but this is just guessing at the orientation
-------- Original Message --------
Subject: mri_convert
Local Time: May 15, 2017 9:58 PM
UTC Time: May 16, 2017 1:58 AM
From: john.ande...@protonmail.com
To: Freesurfer support list <freesurfer@nmr.mgh.harvard.edu>
Dear Freessurfer experts,
i want to convert IMA files to nifti using mri_convert I did the following:
mri_convert 54365413.ima output.nii
I got this error
WARNING: bad orientation matrix (determinant = 0) in nifti1 file ...
... continuing.
if I run mri_info on output.nii I see
voxel-to-ras determinant 0
ras to voxel transform:
mat = NULL!
MatrixFree: NULL mat POINTER!
How can I correctly convert IMA to nifti
Thank you for any suggestion
John