Not sure if this is standard, but on an idle machine (ie. just set it up,
nothing running on it yet), with RAID1+0 across 4 drives:
Writing the 853 Megabyte file, 'iozone.tmp'...15.656250 seconds
Reading the file...3.921875 seconds
IOZONE performance measurements:
57129601 bytes/second for writing the file
228063191 bytes/second for reading the file
The server is a new DL360 G4p, drives are SAS ...
On Sat, 4 Feb 2006, Ivan Voras wrote:
I need to get a Proliant machine with 2 P3 processors running FreeBSD 6. I
don't know much about the machine, I think it's ML 380 G2 or close to that,
but I have physical access. So far, everything is fine (once the inability to
boot from CD-ROM is circumvented), except one "detail": horrible write
performance on its CISS 5 RAID5 array. I get ~75MB/s burst (large blocks)
reads, and only 5MB/s burst writes. I know how RAID5 works, but still, this
is bad. The machine has been running Linux before this and performance was Ok
- I didn't benchmark it but the "feeling" when working on it was normal,
while on FreeBSD it's noticably slow in mixed read/write load.
Is there anything I can try to improve this? In the verbose boot log there's
a line that says the controller supports "simple, performant and MEMQ" modes,
and the one that's used is "simple" - does this have any influence? If so,
how to change it?
Thanks!
----
Marc G. Fournier Hub.Org Networking Services (http://www.hub.org)
Email: [EMAIL PROTECTED] Yahoo!: yscrappy ICQ: 7615664
_______________________________________________
freebsd-stable@freebsd.org mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-stable