On Aug 19, 2011, at 1:50 PM, Dan Langille wrote:
> Searching on that error message, I was led to believe that identifying the 
> bad sector and
> running dd to read it would cause the HDD to reallocate that bad block.
> 
>  http://smartmontools.sourceforge.net/badblockhowto.html
> 
> However, since ad2 is one half of a gmirror, I don't think this is the best 
> approach.
> 
> Comments?

Reading the underlying failing drive with dd will help identify any other 
questionable sectors.  However, your drive temps are too high-- many vendors 
call out either 50C or 55C as the point where drive reliability becomes 
significantly degraded.

Regards,
-- 
-Chuck

_______________________________________________
freebsd-stable@freebsd.org mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-stable
To unsubscribe, send any mail to "freebsd-stable-unsubscr...@freebsd.org"

Reply via email to