On Mon, Jul 19, 2010 at 5:04 PM, Garrett Moore <garrettmo...@gmail.com>wrote:
> Well, hotswapping worked, but now I have a totally different problem. Just > for reference: > # zpool offline tank da3 > # camcontrol stop da3 > <swap drive> > # camcontrol rescan all > <'da3 lost device, removing device entry'> > # camcontrol rescan all > <'da3 at mpt0 ...', so new drive was found! yay> > # zpool replace tank da3 > *cannot replace da3 with da3: device is too small* > > So I looked at the smartctl output for the old and new drive. Old: > Device Model: WDC WD15EADS-00P8B0 > Serial Number: WD-WMAVU0087717 > Firmware Version: 01.00A01 > User Capacity: 1,500,301,910,016 bytes > > New: > Device Model: WDC WD15EADS-00R6B0 > Serial Number: WD-WCAVY4770428 > Firmware Version: 01.00A01 > User Capacity: 1,500,300,828,160 bytes > > God damnit, Western Digital. What can I do now? It's such a small > difference, is there a way I can work around this? Uff da, I'm pretty sure the answer is no, you would have had to use the smallest device first when creating the pool I think. > My other replacement > drive is the "00R6B0" drive model as well, with the slightly smaller > capacity. > -- Adam Vande More _______________________________________________ freebsd-stable@freebsd.org mailing list http://lists.freebsd.org/mailman/listinfo/freebsd-stable To unsubscribe, send any mail to "freebsd-stable-unsubscr...@freebsd.org"