Paul Mather wrote:
Do you have swap on your geom_mirror?
Yes.
> In earlier versions of
geom_mirror, even a clean shutdown would cause a mirror to be marked degraded if swap was still active. The fix at the time was to amend the stop_cmd in /etc/rc.d/swap1 to do an explicit "swapoff -a" (or similar). Later modifications rendered this explicit step unnecessary.
Yes, that hit me too (on another machine), but it would render a disk stale, it would not become lost.
I also remember a short window in which I experienced the same problem of losing a drive/consumer at reboot when a mirror would become degraded (in my case, due to the TIMEOUT - WRITE_DMA problems I was having with 5.x/6.x). This seemed to go away with a subsequent upgrade.
Hmm, this might be it, altough I'm usinc SCIS, so no DMA stuff...
So, if you are planning to upgrade when 5.4-RELEASE rolls around, you might find that these problems disappear.
I am planning to do that as soon as it's released. I hope it will help.
bye & Thanks
av.
_______________________________________________
[email protected] mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-questions
To unsubscribe, send any mail to "[EMAIL PROTECTED]"