rihad wrote:
Julian Elischer wrote:
rihad wrote:
The change definitely helped! There are now more than 3200 users
online, 460-500 mbps net traffic load, and normally 10-60 (up to 150
once or twice) consistent drops per second as opposed to several
hundred up to 1000-1500 packets dropped per second before the
rebuild. What's interesting is that the drops now began only after
the ipfw table had around 3000 entries, not 2000 like before, so the
change definitely helped. Just how high can maxlen be? Should I try
2048? 4096?
is Hz still 4000?
No, I've set it to 2000 as per recommendations for HZ in NOTES. Should I
try 4000? 6000? 8000? Or maybe just increase the bce queue length and
rebuild? :)
you could try combinations.
_______________________________________________
freebsd-net@freebsd.org mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-net
To unsubscribe, send any mail to "freebsd-net-unsubscr...@freebsd.org"