Hi. I figured I'll give this mailing list a shot in helping me figure out a problem I have.
I have 2 reference boards from LSI, using the mpt driver. Each one has MPI FW revision 1.5.13.0 They repond differently. The PCI-X version LSI1064 reports running in RAID-1 and do NOT get the error message. The PCI-express do get the error message, and thus reports RAID-0 Both are configured as RAID-1 Integrated mirroring. Using the same 2 disks on both, swapping them out back and forth between the testing. NOTE: the behavior is the same with FW version 1.5.12.0 except with 1.5.12.0 I get notify events on which I can report sync percentage. ---------------- ERROR MESSAGE ----------------------- . . mpt_read_cfg_page: Config Info Status 22 mpt_refresh_raid_vol: Failed to read RAID Vol Page(0) mpt0:vol0(mpt0:0:0): Settings (netlog:mpt .. ) mpt0:vol0(mpt0:0:0): 0 Members: mpt0:vol0(mpt0:0:0): RAID-0 - Optimal . . ------------------------------------------------------ Johan . _______________________________________________ freebsd-hackers@freebsd.org mailing list http://lists.freebsd.org/mailman/listinfo/freebsd-hackers To unsubscribe, send any mail to "[EMAIL PROTECTED]"