If these are not the correct foruns for this, please forgive me and tell me which is the correct one.
PS: Please CC: me, since I'm not currently subscribed to these lists.
==================================================== Hi Greg,
I've been a big fan of vinum since it's beggining. I use it for RAID0 and RAID1 solution for lots of servers.
In some RAID0 (stripe) configurations, though, I've had some serious problems. If an underlying disk fails, the respective plex and volume do not fail, as they should. This leads to full corruption of data, but worst of that, leads to a system which believes the data is safe. In one ocasion, for example, the backup ran and overwrote good data with bad data, full of zeros.
I am not fully aware of vinum programming details, but a quick look at 4.9-STABLE, in file vinumstate.c, dated Jul, 7, 2000, at line 588, function update_volume_state() sets volume state to up if plex state is corrupt or better for at least one plex:
for (plexno = 0; plexno < vol->plexes; plexno++) {
struct plex *plex = &PLEX[vol->plex[plexno]]; /* point to the plex */
if (plex->state >= plex_corrupt) { /* something accessible, */
vol->state = volume_up;
break;
}
}
I think this should be like:
if (plex->state > plex_corrupt) { /* something accessible, */
Or, in other words, volume state is up only if plex state is degraded or better.
I did not test this, since the situation is not easy to reproduce, but I think it depends only on the real meaning of the "corrupt" state.
Thanks in advance for your attention,
Jonny
_______________________________________________ [EMAIL PROTECTED] mailing list http://lists.freebsd.org/mailman/listinfo/freebsd-hackers To unsubscribe, send any mail to "[EMAIL PROTECTED]"