On 18/01/2013 10:16 AM, Mark Felder wrote:
On Thu, 17 Jan 2013 16:12:17 -0600, Karim Fodil-Lemelin <fodillemlinka...@gmail.com> wrote:

"SAS controllers may connect to SATA devices, either directly connected using native SATA protocol or through SAS expanders using SATA Tunneled Protocol (STP)." The systems is currently put in place using SATA instead of SAS although its using the same interface and backplane connectors and the drives (SATA) show as da0 in BSD _but_ with the SATA drive we get *much* better performances. I am thinking that something fancy in that SAS drive is not being handled correctly by the FreeBSD driver. I am planning to revisit the SAS drive issue at a later point (sometimes next week).

Your SATA drives are connected directly not with an interposer such as the LSISS9252, correct? If so, this might be the cause of your problems. Mixing SAS and SATA drives is known to cause serious performance issues for almost every JBOD/controller/expander/what-have-you. Change your configuration so there is only one protocol being spoken on the bus (SAS) by putting your SATA drives behind interposers which translate SAS to SATA just before the disk. This will solve many problems.
Not sure what you mean by this but isn't the mpt detecting an interposer in this line:

mpt0: <LSILogic SAS/SATA Adapter> port 0x1000-0x10ff mem 0x99910000-0x99913fff,0x99900000-0x9990ffff irq 28 at device 0.0 on pci11
mpt0: MPI Version=1.5.20.0
mpt0: Capabilities: ( RAID-0 RAID-1E RAID-1 )
mpt0: 0 Active Volumes (2 Max)
mpt0: 0 Hidden Drive Members (14 Max)

Also please not SATA speed in that same hardware setup works just fine. In any case I will have a look.