Thanks, Paul!

I talked to our storage experts and as long as the driver already has 5i
support, then all that's needed is to add the new id (which your patch
does).

Thanks,
John
--------------------------------
John Cagle     [EMAIL PROTECTED]
Principal Member Technical Staff
   Industry Standard Servers
    Hewlett-Packard Company

> -----Original Message-----
> From: Paul Saab [mailto:[EMAIL PROTECTED]] 
> Sent: Thursday, January 30, 2003 7:46 PM
> To: John
> Cc: [EMAIL PROTECTED]
> Subject: Re: Smart Array 5312 (Compaq)
> 
> 
> Try this patch
> 
> http://people.freebsd.org/~ps/ciss.diff
> 
> John ([EMAIL PROTECTED]) wrote:
> > Is anyone working on a driver for said raid controller?
> > Here is a pciconf -lv (from 5.0-R) and a link for some info on the 
> > card.
> > 
> > 
> > ne3@pci6:2:0: class=0x010400 card=0x40830e11 
> chip=0xb1780e11 rev=0x01 hdr=0x00
> >     class    = mass storage
> >     subclass = RAID
> > 
> > 
> http://h18004.www1.hp.com/products/servers/pro>
liantstorage/arraycontro
> > llers/smartarray5312/questionsanswers.html
> > 
> > To Unsubscribe: send mail to [EMAIL PROTECTED]
> > with "unsubscribe freebsd-current" in the body of the message
> 
> -- 
> Paul Saab
> Technical Yahoo
> [EMAIL PROTECTED] - [EMAIL PROTECTED] - [EMAIL PROTECTED]
> Do You .. uhh .. Yahoo!?
> 
> To Unsubscribe: send mail to [EMAIL PROTECTED]
> with "unsubscribe freebsd-current" in the body of the message
> 

To Unsubscribe: send mail to [EMAIL PROTECTED]
with "unsubscribe freebsd-current" in the body of the message

Reply via email to