https://bugs.freebsd.org/bugzilla/show_bug.cgi?id=209202

Justin Hibbits <jhibb...@freebsd.org> changed:

           What    |Removed                     |Added
----------------------------------------------------------------------------
                 CC|                            |jhibb...@freebsd.org

--- Comment #6 from Justin Hibbits <jhibb...@freebsd.org> ---
I see you changed the hysteresis timer to 30 seconds, does the quad need a
longer time before settling?  I thought 10 seconds should be sufficient for
most cases, to cool the system down well below the target before dropping down.
 But if 30 seconds is needed, then I'm fine with that change.

-- 