I've tracked down the error in the DOLFIN fem unit test to the following simple test:
from dolfin import * mesh = UnitSquare(1, 1) V = FunctionSpace(mesh, "DG", 1) v = TestFunction(V) u = TrialFunction(V) h = CellSize(mesh) a = (1/h)*v*u*ds A = assemble(a) info(A, True) With the old FFC, the result is row 0: (0, 0.235702) (1, 0.117851) (2, 0) row 1: (0, 0.117851) (1, 0.707107) (2, 0.235702) row 2: (0, 0) (1, 0.235702) (2, 0.471405) row 3: (3, 0.707107) (4, 0.353553) (5, 0) row 4: (3, 0.353553) (4, 1.64992) (5, 0.471405) row 5: (3, 0) (4, 0.471405) (5, 0.942809) With the new FFC, the result is instead row 0: (0, 0.235702) (1, 0.117851) (2, 0) row 1: (0, 0.117851) (1, 0.471405) (2, 0.117851) row 2: (0, 0) (1, 0.117851) (2, 0.235702) row 3: (3, 0.235702) (4, 0.117851) (5, 0) row 4: (3, 0.117851) (4, 0.471405) (5, 0.117851) row 5: (3, 0) (4, 0.117851) (5, 0.235702) -- Anders