I just wanted a quick sanity check. I've installed a Mylex AcceleRAID 170 (see
earlier note) with three Cheetah's attached. After almost every reboot, the
controller reports a drive failure on the disk closest to the controller, but
with the highest SCSI id, 2. There was one exception where the next closest disk
(id one less as well - 1) was reported as failed.

Anyone else think I need a terminator on the end of the chain? I was hoping for
auto to handle it, but I guess I won't be that lucky.

John LeMay Jr.
Senior Enterprise Consultant
NJMC, LLC.


Reply via email to