On Fri, 8 Sept 2023 at 17:07, gene heskett <[email protected]> wrote:
> Now I've another data missmatch, since when is a "not" not a true/false
> invertor? I can't feed it into a mux2 in for the sample to hold???
What is the datatype of your mux2?
Works for me:
andypugh@rm-one:~/linuxcnc-dev$ halrun
halcmd: loadrt not count=1
Note: Using POSIX realtime
halcmd: loadrt mux_generic config=bb2
halcmd: net test not.0.out mux-gen.00.in-bit-01
halcmd: show sig
Signals:
Type Value Name (linked to)
bit FALSE test
==> mux-gen.00.in-bit-01
<== not.0.out
--