Thanks Peter!

El vie., 17 de marzo de 2023 15:54, Peter C. Wallace <[email protected]>
escribió:

> On Fri, 17 Mar 2023, Leonardo Marsaglia wrote:
>
> > Date: Fri, 17 Mar 2023 15:14:28 -0300
> > From: Leonardo Marsaglia <[email protected]>
> > Reply-To: "Enhanced Machine Controller (EMC)"
> >     <[email protected]>
> > To: "Enhanced Machine Controller (EMC)" <[email protected]
> >
> > Subject: [Emc-users] 7i95 stepgen in single ended mode
> >
> > Hi guys,
> >
> > Just to be sure. Are the 7i95 stepgen pins meant to be used as single
> ended
> > besides differential? Because every group of differential pins lie
> between
> > a ground and a 5v output so I guess this is meant to be used in both ways
> > depending on the configuration.
> >
> > Thanks as always!
> >
> > Leonardo
> >
>
>
> Yes, the step/dir pins can be used single ended or differentially.
>
>
> Differential:
>
> STEP+ PUL+
> STEP- PUL-
>
> Single ended sourcing:
>
> STEP+ PUL+
> GND   PUL-
>
> Single ended sinking:
>
> +5V   PUL+
> STEP- PUL-
>
>
>
>
> > _______________________________________________
> > Emc-users mailing list
> > [email protected]
> > https://lists.sourceforge.net/lists/listinfo/emc-users
> >
>
> Peter Wallace
> Mesa Electronics
>
> (\__/)
> (='.'=) This is Bunny. Copy and paste bunny into your
> (")_(") signature to help him gain world domination.
>
>
>
> _______________________________________________
> Emc-users mailing list
> [email protected]
> https://lists.sourceforge.net/lists/listinfo/emc-users
>