Greetings all;

It would be handier than a bottled beer, if there was an m-code I could 
hack up to do a setp. Do we have such a critter? I want to zero a counter 
module from the mdi command line. Or from an nc file, either way would 
work.

My 50/1 3d printed harmonic drive finally puked last night after nearly 9 
months of exersize, and I have a set of what should be longer lasting 
40/1 guts to put in it.

I use the counter to count home switch closures to drive a pair of comps, 
one set to freeze the fb value from the stepgen on the 3 to 4 transition, 
and another freezes the fb value on the 103-104 trasition, the 1st 
subtracted from the second and displayed on a halmeter. A /100 then 
becomes the SCALE value for that rotary axis in the .ini file.

Thank you.

Cheers, Gene Heskett.
-- 
"There are four boxes to be used in defense of liberty:
 soap, ballot, jury, and ammo. Please use in that order."
-Ed Howdershelt (Author, 1940)
If we desire respect for the law, we must first make the law respectable.
 - Louis D. Brandeis