On 12/26/2020 10:47 AM, Gene Heskett wrote:
Two additional questions. That 70 ohm 300 watt braking resistor just walked up and rang my doorbell, so are you using one? and if so what settings mods have you made in the VFD?
Mine has several settings. There is a minimum frequency, below which it goes to DC injection braking. You don't want to use too much DC injection as it will cause an abrupt stop of the motor. Quicker braking time will cause more energy to go to the resistor, if you set it too short, the DC link may go to overvoltage. You may have to just experiment a bit to find out what decel times make sense on your particular machine. If you rigid tap, you need a braking resistor to reduce the overrun after you get to desired depth.

Jon


_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to