On Tuesday 05 March 2019 22:34:27 a k wrote: > Hi > i found this mfg of ac servo and drive > http://www.dmm-tech.com/products_main.html > > did anyone used try this motor+drive? > it is close loop system > and manufacture said that on LCNC i can use 2 motor drive that i had > from 2003 and one axis will be use this DMM teck motor+ drive > > Big question : is it possible on one system LCNC have 2 axis using > open loop (where software tune axis) and one axis that is close loop? > > thank you > aram > I don't see why not. The closed loop drive has the ability to issue an e-stop if it gets out of synch and can't fix it, and you should add that alarm pin to the lcnc e-stop logic in your hal file. Otherwise if its running ok. lcnc has no clue its running a smarter device.
> _______________________________________________ > Emc-users mailing list > [email protected] > https://lists.sourceforge.net/lists/listinfo/emc-users Cheers, Gene Heskett -- "There are four boxes to be used in defense of liberty: soap, ballot, jury, and ammo. Please use in that order." -Ed Howdershelt (Author) Genes Web page <http://geneslinuxbox.net:6309/gene> _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users