On 22 April 2016 at 01:02, Danny Miller <[email protected]> wrote:
> RS274NGC_STARTUP_CODE = G17 G20 G40 G49 G64 P0.001 G80 G90 G92 G94 G97 G98
>
> Sure.  And I do.  But I don't train people to reboot LinuxCNC every time
> they start, and I don't plan to.

One useful addition to the system might be a "reset defaults" physical
button on the panel somewhere. That could be linked to an MDI_COMMAND
that resets all offsets etc.

It could, possibly, run a routine to zero all the tool offsets too.
But that might take a bit of cunning as I think that G10 probably
errors if you try to set an offset for a tool not in the table.

-- 
atp
"A motorcycle is a bicycle with a pandemonium attachment and is
designed for the especial use of mechanical geniuses, daredevils and
lunatics."
— George Fitch, Atlanta Constitution Newspaper, 1916

------------------------------------------------------------------------------