Just talked to the operator, he said he would rather have all three 
options, so I told him they were either going to have to remember to add 
an M28 " Thru-spindle Off" to shut it off in the programs, or modify the 
post processor they use to include this with every M09 issued.

Maybe I will put in a feature request to allow minimal remapping of M09, 
or add a thru spindle coolant option in general.

Thanks for the help though Andy,

Rick


On 6/2/2015 1:58 PM, andy pugh wrote:
> On 2 June 2015 at 18:50, andy pugh <[email protected]> wrote:
>
>> setp mist.function 0x2
>> setp through-spindle.function 0x8
> I should perhaps make it clear that this setup has no way to have
> through-spindle only. There are only four options with the two IO
> pins, so assuming you want an all-off mode only three of mist / flood
> / spindle / mist + spindle / flood + spindle / mist + flood / mist +
> flood + spindle can be set up.
>
> A custom HAL component could be written whereby mist-only, flood-only,
> mist then flood, flood then mist gave 4 out of the 7.
>

-- 

Thanks