2015-03-11 15:08 GMT-03:00 rayj <[email protected]>:

> Looks like a good process.  What frequency,voltage and amperage are you
> using?
>

The heater runs up to 97 amps (per phase) and depending on the lobe to heat
we're using it with more or less current. The minimum we're using is about
40 amps.

Voltage is about 650 v when rectified if I'm not wrong because it takes the
three phase 380 v from the line.

Frequency goes from a minimum of 10 Khz to a maximum of 30 Khz depending on
the coil, because it has a phase locked loop to mantain the resonance at
all times. Frequency is not that critical, since you can play with the
amount of power and the heating time to change the depth and the value of
the hardness to reach. Also an exquisite way of controlling that is to vary
the temperature of the water to cool the part.


-- 
*Leonardo Marsaglia*.
------------------------------------------------------------------------------