> Peter, I tried use the pncconf to setup the conf.  It seems that even
> though I put the X axis stepgen on 0 and 3 in the configuration... only the
> 3 makes it into the hal file.
> 
> 

Yes this is a limitation of PNCconf.
What you can do is call the second axis something else just type in the name 
you would like.
such as X2.
If you look in the HAL file and the INI file you will see entries related to 
this name.
Then in a custom HAL file setup and connect this stepgen to the same 
settings/signals as X