Back in 2015, in my paper at the Institute of Physics in Southampton, England, 
I showed how 800 Volt ESD or EFT events can break over a 1500 VRMS (~2100 V 
peak) barrier in a power supply involving ringing in the EMC power line filter. 
This would be a low energy discharge, however it may degrade the barrier over 
time as 800 Volt EFT events on the power line are very common. Even a single 
small spark can trigger a large one and cause a safety issue, a single event!

I think there is a safety problem here that is a disaster waiting to happen.

Thoughts!