Hello,

Samuel Wales <samolog...@gmail.com> writes:

> recent maint.
>
> just wondering what i could be doing wrong.
>
> it is /usually/ the case that i get clock start tmie is gone when i
> try to clock out.

This is odd, as this shouldn't be usual.

> it isn't gone.  so i do org-clock-cancel, which is slow.  this leaves
> the start time.
>
> so i do org-clock-in, which presents me with all the options.  i
> choose K because i want to be clocked out.
>
> but it ignores the K and keeps me clocked in.
>
> so i clock out.  btw, clocking out is slow.
> org-clock-remove-empty-clock-drawer takes up 95% of the time.

It is possible if you have really large clock drawers, i.e., hundreds of
clocks in it.

> and this leaves me with a correct clock line and a new clock line with
> 0 time on it.
>
> so then i have to kill the new clock line.

It would be nice to have an ECM for this report, with emphasis on the
"M".

Regards,

-- 
Nicolas Goaziou