The fault table should show what threshold is being exceeded. Recent 160 meter 
soft fault detail would be of interest.

73 de Dick, K6KR

> On Nov 17, 2023, at 19:51, Pete Smith N4ZR <pete.n...@gmail.com> wrote:
> 
> I have just tried my K-3/KPA-1500 combo on 160.  I find that I can only 
> increase the drive to 26 watts, to deliver about 880 watts input before the 
> OVR light comes on.  Is this to be expected?  Don't see anything in the 
> manual about it.
> 
> -- 
> 73, Pete N4ZR
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:Elecraft@mailman.qth.net
> 
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
> Message delivered to d...@elecraft.com
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com 

Reply via email to