Thanks, Don.  It’s a K2/10, so I’ll do the relay touch-test.

Dave   K9SW



> On Jul 24, 2021, at 8:40 PM, Don Wilhelm <[email protected]> wrote:
> 
> Dave,
> 
> I am at a loss to tell you what is going on.  The T/R switching in the K2 is 
> all electronic, no relays involved.
> If a K2/100, break it down to just the base K2 and see if it is in the base 
> K2 or in the KPA100.
> If you have the K2/10, remove the top cover which contains the KAT2.
> 
> If it occurs in just the base K2, hold your finger on the relays one by one 
> and see if you can detect which one is switching as you key the K2.
> 

> 73,
> Don W3FPR
> 
> On 7/24/2021 5:22 PM, K9SW wrote:
>> Recently bought a K2 and all was working well (silent QSK) until I moved 
>> from one spot on the bench to another.  It was powered up and one of the 
>> leads fell off the power supply connector, so this was a live power 
>> interruption.  After this, there are relay clicks when sending CW.  I did a 
>> reset, but this did not change the relay clicks.  Built the probe and did 
>> the CAL FIL routine and got it back on the air successfully.
>> 
>> S/N 100, with ATU and SSB board.
>> 
>> It would be nice to get back to silent QSK and preserve relay life.  Any 
>> suggestions appreciated!
>> 
>> 
> 