I recall a couple years ago I ran in circles with this.  My error was caused by 
dirt/corrosion between pcb pads "underneath" a resistor on the pll board.  I 
don't have everything handy but you might try swapping the cable on the board 
that plugs into the pl1 output to the pl2 output that would go to rx2 if you 
aren't using a second rx.
Mike WA8EBM
Date: Mon, 1 Aug 2011 21:11:09 -0400
From: "Jim Spears" <[email protected]>
Subject: [Elecraft] [K3] ERR PL1 has shown up
To: <[email protected]>
Cc: 'Gary Surrency' <[email protected]>
Message-ID: <003801cc50b1$104da820$30e8f860$@net>
Content-Type: text/plain; charset="us-ascii"

Yesterday I got an ERR PL1 when changing to 12m.  I did a VCO CAL and it
went away.  This evening, I changed to 20m and got ERR PL1 again.  I did a
VCO CAL and it did not go away but showed up with an E 000129 ERR VCO.
Since I am on east coast, many Elecrafters will see this before the support
elves come on line Tuesday morning.  suggestions?