> > I can perfectly use my sipgate account with kphone, but with ekiga only > > the registration works (that is, calling in/out does not work with > > ekiga).
[...] > > Is there a way to reset the gconf-editor settings to default values? If > > not wherre can I find the defaults, so that I can reset it manually. > > gconftool-2 -u -R /apps/ekiga should work (out of the top of my head, so > no warranty). almost, it is "gconftool-2 --recursive-unset /apps/ekiga". Anyway, it still does not work, so this does not seems to be the problem. The problem again: I can register with sipgate.de (and also unregister) perfectly. But when I call sip:[EMAIL PROTECTED] (a test number, but the same holds true for every other number), then I can here it ringing, but after about 10 sec. it stops ringing. With kphone, the test call (as well as others) works perfectly. Since it works with kphone, I guess that it cannot be the firewall (I have stun enabled (stun.sipgate.de:10000) as said by the setup wizard (I have a very common NAT'ed router with no special software on it; "Port Restricted NAT" said the wizard) When there is an incoming call, then ekiga announces this rightly, but when I take the call, it says "Abnormal call termination". I'd think it something with RTP. any ideas? jens _______________________________________________ ekiga-list mailing list ekiga-list@gnome.org http://mail.gnome.org/mailman/listinfo/ekiga-list