Thank you for your contribution! Sashiko AI review found 1 potential issue(s) to consider: - [Medium] drm/exynos: hdmi_get_modes() calls cec_notifier_set_phys_addr() with no EDID --
commit f0dacf81d55b2fd1b8fee4812c0ecf88da4b0a39 Author: Hans Verkuil <[email protected]> gpu: drm: exynos: call cec_notifier_phys_addr_invalidate if no EDID This commit updates hdmi_detect() in exynos_hdmi to call cec_notifier_phys_addr_invalidate() instead of cec_notifier_set_phys_addr() with CEC_PHYS_ADDR_INVALID when the connector is disconnected. > diff --git a/drivers/gpu/drm/exynos/exynos_hdmi.c > b/drivers/gpu/drm/exynos/exynos_hdmi.c > index 055dc04f9b3e5..d03f4e531e05e 100644 > --- a/drivers/gpu/drm/exynos/exynos_hdmi.c > +++ b/drivers/gpu/drm/exynos/exynos_hdmi.c > @@ -857,7 +857,7 @@ static enum drm_connector_status hdmi_detect(struct > drm_connector *connector, > if (gpiod_get_value(hdata->hpd_gpio)) > return connector_status_connected; > > - cec_notifier_set_phys_addr(hdata->notifier, CEC_PHYS_ADDR_INVALID); > + cec_notifier_phys_addr_invalidate(hdata->notifier); [Severity: Medium] The commit message notes that cec_notifier_set_phys_addr() should be called if an EDID is present and cec_notifier_phys_addr_invalidate() if not, so the CEC framework can distinguish between CEC_PHYS_ADDR_INVALID due to a missing EDID versus an EDID without a physical address. While this updates the disconnect path in hdmi_detect(), hdmi_get_modes() in drivers/gpu/drm/exynos/exynos_hdmi.c still calls cec_notifier_set_phys_addr() before checking whether drm_edid is NULL: drivers/gpu/drm/exynos/exynos_hdmi.c:hdmi_get_modes() { ... drm_edid = drm_edid_read_ddc(connector, hdata->ddc_adpt); ret = drm_edid_connector_update(connector, drm_edid); if (ret) return 0; cec_notifier_set_phys_addr(hdata->notifier, info->source_physical_address); if (!drm_edid) goto no_edid; ... } When drm_edid_read_ddc() returns NULL during mode probing via drm_helper_probe_single_connector_modes() -> hdmi_get_modes(), drm_edid_connector_update() resets info->source_physical_address to CEC_PHYS_ADDR_INVALID, and hdmi_get_modes() passes that to cec_notifier_set_phys_addr() even though no EDID was read. Should hdmi_get_modes() also check for a NULL drm_edid first and call cec_notifier_phys_addr_invalidate(hdata->notifier) on the no_edid path instead of cec_notifier_set_phys_addr()? -- Sashiko AI review ยท https://sashiko.dev/#/patchset/80b02c6057f32dd8be8b4de95d1cd27352cdddc8.1793691124.git.hverkuil+ci...@kernel.org?part=1