Hi Dmitry, On Sun, 30 Mar 2025 at 18:56, Dmitry Baryshkov <dmitry.barysh...@oss.qualcomm.com> wrote: > > On Sun, Mar 30, 2025 at 06:49:40PM +0100, Christopher Obbard wrote: > > According to the eDP specification (VESA Embedded DisplayPort Standard > > v1.4b, Section 3.3.10.2), if the value of DP_EDP_PWMGEN_BIT_COUNT is > > less than DP_EDP_PWMGEN_BIT_COUNT_CAP_MIN, the sink is required to use > > the MIN value as the effective PWM bit count. > > > > This commit updates the logic to clamp the reported > > DP_EDP_PWMGEN_BIT_COUNT to the range defined by > > DP_EDP_PWMGEN_BIT_COUNT_CAP_MIN and _CAP_MAX. As part of this change, > > the behavior is modified such that reading _CAP_MIN and _CAP_MAX > > registers is now required to succeed. Before reading these registers > > was optional. > > Describe why, not what. Something like 'is now required to succeed, > otherwise bl->max value can end up being not set, although > drm_edp_backlight_probe_max() returned success'. > > LGTM otherwise.
Amazing. We got there eventually! I updated the commit message around this change to be: As part of this change, the behavior is modified such that reading both _CAP_MIN and _CAP_MAX registers is now required to succeed, otherwise bl->max value could end up being not set although drm_edp_backlight_probe_max() returned success. I will wait for more feedback for few days before sending the next version. Cheers! Chris