Il 16/04/24 17:53, Alexandre Mergnat ha scritto:
According to the Mediatek MT8365 datasheet, the display PWM block has
a power domain.

Signed-off-by: Alexandre Mergnat <amerg...@baylibre.com>

It's the same for at least MT8195, MT8183 and I think MT8192 as well... so
not having that from the beginning is actually a mistake.

Please add a Fixes tag and resend, after which:

Reviewed-by: AngeloGioacchino Del Regno 
<angelogioacchino.delre...@collabora.com>