Il 16/04/24 17:53, Alexandre Mergnat ha scritto:
According to the Mediatek MT8365 datasheet, the display PWM block has a power domain.Signed-off-by: Alexandre Mergnat <amerg...@baylibre.com>
It's the same for at least MT8195, MT8183 and I think MT8192 as well... so not having that from the beginning is actually a mistake. Please add a Fixes tag and resend, after which: Reviewed-by: AngeloGioacchino Del Regno <angelogioacchino.delre...@collabora.com>