From: ChiYuan Huang <cy_hu...@richtek.com>

Add 'richtek,bled-ocp-microamp' property to make it chooseable.

The wrong backlight ocp level may affect the backlight channel output
current smaller than configured.

Signed-off-by: ChiYuan Huang <cy_hu...@richtek.com>
---
Since v2:
- Change the property name from 'richtek,bled-ocp-sel' to 
'richtek,bled-ocp-microamp'.

---
 .../devicetree/bindings/leds/backlight/richtek,rt4831-backlight.yaml | 5 +++++
 1 file changed, 5 insertions(+)

diff --git 
a/Documentation/devicetree/bindings/leds/backlight/richtek,rt4831-backlight.yaml
 
b/Documentation/devicetree/bindings/leds/backlight/richtek,rt4831-backlight.yaml
index e0ac686..0f4beeb 100644
--- 
a/Documentation/devicetree/bindings/leds/backlight/richtek,rt4831-backlight.yaml
+++ 
b/Documentation/devicetree/bindings/leds/backlight/richtek,rt4831-backlight.yaml
@@ -47,6 +47,11 @@ properties:
     minimum: 0
     maximum: 3
 
+  richtek,bled-ocp-microamp:
+    description: |
+      Backlight over current protection level, unit in microamp. The current
+      supported level is 0.9A/1.2A/1.5A/1.8A.
+
   richtek,channel-use:
     description: |
       Backlight LED channel to be used.
-- 
2.7.4