Hi Philipp,

On 08/02/2018 02:42 AM, Philipp Zabel wrote:
Hi Steve,

On Wed, 2018-08-01 at 12:12 -0700, Steve Longerbeam wrote:
When the CSI is receiving from a bt.656 bus, include a check for
field type 'alternate' when determining whether to set CSI clock
mode to CCIR656_INTERLACED or CCIR656_PROGRESSIVE.

Signed-off-by: Steve Longerbeam <steve_longerb...@mentor.com>
---
  drivers/gpu/ipu-v3/ipu-csi.c | 3 ++-
  1 file changed, 2 insertions(+), 1 deletion(-)

diff --git a/drivers/gpu/ipu-v3/ipu-csi.c b/drivers/gpu/ipu-v3/ipu-csi.c
index caa05b0..5450a2d 100644
--- a/drivers/gpu/ipu-v3/ipu-csi.c
+++ b/drivers/gpu/ipu-v3/ipu-csi.c
@@ -339,7 +339,8 @@ static void fill_csi_bus_cfg(struct ipu_csi_bus_config 
*csicfg,
                break;
        case V4L2_MBUS_BT656:
                csicfg->ext_vsync = 0;
-               if (V4L2_FIELD_HAS_BOTH(mbus_fmt->field))
+               if (V4L2_FIELD_HAS_BOTH(mbus_fmt->field) ||
+                   mbus_fmt->field == V4L2_FIELD_ALTERNATE)
                        csicfg->clk_mode = IPU_CSI_CLK_MODE_CCIR656_INTERLACED;
                else
                        csicfg->clk_mode = IPU_CSI_CLK_MODE_CCIR656_PROGRESSIVE;
this patch is already merged in v4.18-rc7.

Ah, I just noticed that after a fetch from kernel.org, thanks.

Steve