On 2017-09-05 18:26, Dhinakaran Pandiyan wrote:
> The POWER_DOWN_PHY and POWER_UP_PHY sideband message transactions allow
> the source to reqest any node in a mst path or a whole path to be
> powered down or up. This allows drivers to target a specific sink in the
> MST topology, an improvement over just power managing the imediate
> downstream device. Secondly, since the request-reply protocol waits for an
> ACK, we can be sure that a downstream sink has enough time to respond to a
> power up/down request.
> 
> Cc: Lyude <ly...@redhat.com>
> Cc: Ville Syrjälä <ville.syrj...@linux.intel.com>
> Cc: Harry Wentland <harry.wentl...@amd.com>
> Signed-off-by: Dhinakaran Pandiyan <dhinakaran.pandi...@intel.com>

Tested-by: Stefan Assmann <sassm...@redhat.com>
_______________________________________________
dri-devel mailing list
dri-devel@lists.freedesktop.org
https://lists.freedesktop.org/mailman/listinfo/dri-devel

Reply via email to