> >>  Optional properties:
> >>  - fsl,tcon:               The phandle to the timing controller node.
> >> @@ -24,6 +24,11 @@ dcu: dcu at 2ce0000 {
> >>    clocks = <&platform_clk 0>, <&platform_clk 0>;
> >>    clock-names = "dcu", "pix";
> >>    big-endian;
> >> -  fsl,panel = <&panel>;
> >>    fsl,tcon = <&tcon>;
> >> +
> >> +  port: port at 0 {
> >
> > Drop the unit address. With that,
> 
> I was going to say add a corresponding reg property and specify address-cells.
> 

For now, we only have one 'remote-endpoint', you mean maybe we should
use 'ports' that prepare for multiple connections?

> So is it ok to also create a port without address?
> 

It works fine, I think it is ok.

Best Regards,
Meng