On Fri, Jun 26, 2015 at 12:27:09PM +0200, Lucas Stach wrote:
> From: Philipp Zabel <p.zabel at pengutronix.de>
> 
> According to the data sheet, the minimum horizontal blanking interval
> is 54 clocks (1 + 52 + 1), but tests with a Nitrogen6X have shown the
> minimum working horizontal blanking interval to be 60 clocks.
> 
> Signed-off-by: Philipp Zabel <p.zabel at pengutronix.de>
> Signed-off-by: Lucas Stach <l.stach at pengutronix.de>
> ---
>  drivers/gpu/drm/panel/panel-simple.c | 7 ++++++-
>  1 file changed, 6 insertions(+), 1 deletion(-)
> 
> diff --git a/drivers/gpu/drm/panel/panel-simple.c 
> b/drivers/gpu/drm/panel/panel-simple.c
> index dc6a923c89d7..7196b940a928 100644
> --- a/drivers/gpu/drm/panel/panel-simple.c
> +++ b/drivers/gpu/drm/panel/panel-simple.c
> @@ -713,7 +713,12 @@ static const struct display_timing 
> hannstar_hsd070pww1_timing = {
>       .hactive = { 1280, 1280, 1280 },
>       .hfront_porch = { 1, 1, 10 },
>       .hback_porch = { 1, 1, 10 },
> -     .hsync_len = { 52, 158, 661 },
> +     /*
> +      * According to the data sheet, the minimum horizontal blanking interval
> +      * is 54 clocks (1 + 52 + 1), but tests with a Nitrogen6X have shown the
> +      * minimum working horizontal blanking interval to be 60 clocks.
> +      */
> +     .hsync_len = { 58, 158, 661 },

58 != 60, so which one is the truth here?

Thierry