Hi list
I'm testing drbd C protocol with two ext4 partitions on 2 banana pi's and I
noticed that"C protocol does not stop a copying process into the master mount,
while I disconnect the slave network cable: There is a short delay in copying,
but the process then continues with /proc/drbd mentioning "Network failure" and
"Waiting for connection" plus slave being in inconsistent state. re-plugging
the slave network cable will trigger a successful sync form master to slave and
both are up-to-date again.
My question is simply this: how come C protocol does not block master mount
write access, when data can not safely be written to the slave? Is this
considered a heartbeat's task, so drbd does not react itself? Or can I modify
the drbd.conf, so at least disk writes into the master are stopped when the
slave is disconnected?
Attached is my minimalistic drbd.conf
cat /etc/drbd.conf
global { usage-count no; }
common { syncer { rate 100M; } }
resource r0 {
protocol C;
startup {
wfc-timeout 15;
degr-wfc-timeout 60;
}
net {
cram-hmac-alg sha256;
shared-secret "secret";
}
on Pi1 {
device /dev/drbd0;
disk /dev/sda1;
address 192.168.1.11:7789;
meta-disk internal;
}
on Pi2 {
device /dev/drbd0;
disk /dev/sda1;
address 192.168.1.12:7789;
meta-disk internal;
}
}
There is no heartbeat service involved as of now, so I'm assigning roles myself
with drbdadm.
Regards
Mayk