I'm getting the following failed test:
test-var-expand.c:464: Assert failed: labs(t0 - t1) < 10
3600 < 10 is not true
var_expand(providers) ................................................ :
FAILED
This test appears to be a timestamp comparison as per this comment:
/* Ensure the time is within 10 seconds */
being exactly one hour off makes me suspect a time-zone issue on the
build machine. This machine is in NZDT which is currently in daylight
savings time which makes me suspect that this is an issue that is
specific to dovecot being built in a timezone in the southern hemisphere.
Shouldn't the comparison be done on UTC time instead of localtime to
avoid these issues?
Peter