On Fri, 01 Jun 2018 03:40:07 +0900, Timo Sirainen wrote: > >> When running multiple instances of dovecot on the same host (or running > >> multiple docker container), > >> it is hard to distinguish logs from different processes: the syslog > >> entries are all prefixed with the same identifier "dovecot" > >> It is hardcoded here: > >> https://github.com/dovecot/core/blob/master/src/lib-master/master-service.c#L420 > >> > >> Would it make sense to use the already implemented instance-name as syslog > >> ident? > >> How do others solve that problem? > > > > I have a patchset to implement that. Please see the attachment. > > > Subject: [PATCH 1/2] master: Do not prepend "dovecot-" to a process name > > Why not? I'd think it would be useful to always find dovecot processes.
I want to use 'director/*' names, not 'dovecot-director/*' for short name. > > - openlog(ident, options, facility); > > + static char *syslog_ident = NULL; > > + > > + i_free(syslog_ident); > > + syslog_ident = i_strdup(ident); > > + > > + openlog(syslog_ident, options, facility); > > > I don't think this is necessary? Sorry. I'm not expert of Dovecot implementation... > > + env_put(t_strconcat("INSTANCE_NAME=", set->instance_name, > > NULL)); > > Also not needed. I think $INSTANCE_NAME environment variable is useful for external program, e.g., custom checkpassword program. > But yeah, I guess in general it would make sense to use instance_name for > syslog ident. > Thanks. -- -- Name: SATOH Fumiyasu @ OSS Technology Corp. (fumiyas @ osstech co jp) -- Business Home: https://www.OSSTech.co.jp/ -- GitHub Home: https://GitHub.com/fumiyas/ -- PGP Fingerprint: BBE1 A1C9 525A 292E 6729 CDEC ADC2 9DCA 5E1C CBCA