On Apr 24, 2012, at 3:40 PM, Hans Breuer wrote:
> This is not the way backward compatibility is handled in Dia. The right 
> behaviour would be to initialize to the previous default without any warning 
> whatsoever.


OK.  But I don't see how to set the default value for a missing
optional property.  It seems to set to the object creation default,
which will be whatever the current default start arrow is at load
time; this is obviously wrong.  I need to override this to "no arrow"
when loading an old file.  Suggestions?