On Mon, 14 Apr 2025, Hal Murray wrote:
I do know that the SO_* symbols are for the socket options and the SCM_*
symbols are for the CMSG types, so I don't see how this could possibly be
correct. Note the code immediately above it.
The OLD stuff is a mess.
I did it the way you expect, but that didn't work because
SCM_TIMESTAMPNS_OLD didn't exist.
All the SCM symbols are setup useing the SO sysmbols.
#define SCM_foo SO_foo
So I use the SO_ symbols.
The code works for the test case and still works on quite a few normal
cases.
If the values are identical, then it's not functionally incorrect, but
it's certainly conceptually incorrect to compare an SO_* value to a
cmsg_type field. And if the values are identical, it wouldn't change the
behavior to use the correct name.
Fred Wright