----- Original Message ----- > From: "Ryan Moats" <rmo...@us.ibm.com> > To: dev@openvswitch.org > Sent: Friday, July 22, 2016 5:54:26 PM > Subject: [ovs-dev] [PATCH] ovn-controller: Handle physical changes correctly > > [1] reported increased failure rates in certain tests > with incremental processing (the numbers are the number of failures > seen in 100 tests): > > 2 ovn -- vtep: 3 HVs, 1 VIFs/HV, 1 GW, 1 LS > 10 ovn -- 2 HVs, 2 LS, 1 lport/LS, 2 peer LRs > 52 ovn -- 1 HV, 1 LS, 2 lport/LS, 1 LR > 45 ovn -- 1 HV, 2 LSs, 1 lport/LS, 1 LR > 23 ovn -- 2 HVs, 3 LS, 1 lport/LS, 2 peer LRs, static routes > 53 ovn -- 2 HVs, 3 LRs connected via LS, static routes > 32 ovn -- 2 HVs, 2 LRs connected via LS, gateway router > 50 ovn -- icmp_reply: 1 HVs, 2 LSs, 1 lport/LS, 1 LR > > These failures were caused by a combination of problems in > handling physical changes: > > 1. When a vif was removed, the localvif_to_ofport entry was not > removed. > 2. When a physical change was detected, ovn-controller would wait > a poll cycle before processing the logical flow table. > > This patch set addresses both of these issues while simultaneously > cleaning up the code in physical.c. A side effect is a modification > of where OF flows are dumped in the gateway router case that allowed > the root causes of this issue to be found. > > With these changes, all of the above tests had a 100/100 success rate. > > [1] http://openvswitch.org/pipermail/dev/2016-July/075803.html > > Signed-off-by: Ryan Moats <rmo...@us.ibm.com>
Hi Ryan, Belated ACK since this is already applied, tests are looking *much* better. Thanks! Lance _______________________________________________ dev mailing list dev@openvswitch.org http://openvswitch.org/mailman/listinfo/dev